| 測(cè)試電流 |  | 
 
 |  | AC 3A ~ 32A | 
 
 | 測(cè)試電壓 | 
 
 |  | 最大 8V AC Typically | 
 
 | 量測(cè)阻抗范圍 | 
 
 |  | 0 to 0.12Ω, 0 to 0.6Ω共 2 檔 | 
 
 | 量測(cè)準(zhǔn)確度 | 
 
 |  | 3A ~ 5A, + 10% 滿刻度 5A ~ 32A, + 5% 滿刻度
 | 
 
 | 電流表 | 
 
 |  | 顯示測(cè)試電流及警告設(shè)限值 | 
 
 | 阻抗表 | 
 
 |  | 顯示測(cè)試電阻及 Fail 與 SUBTRACTION 設(shè)定值 | 
 
 | 切換開關(guān) | 
 
 |  | Zero-start operating switch | 
 
 | 計(jì)時(shí)器 | 
 
 |  | 1S, 10S, 1MIN, 10MIN 共 4 檔 | 
 
 | 警告 | 
 
 |  | Monitor the variation test current, when the test current is beyond + 10% of the setting value, the warning operation will proceed. 警告設(shè)定范圍 3A ~ 32A
 | 
 
 | SUBTRACTION | 
 
 |  | The resistance of testing line can be subtracted from the test value The subtraction range from 0 ~ 0.1Ω
 準(zhǔn)確度 + 10%
 | 
 
 | GO-NOGO判定設(shè)定 | 
 
 |  | If the test reading value is beyond the setting value, the fail will be acting, otherwise the pass will proceed. 設(shè)定值范圍,為測(cè)試檔位的 5% ~ 100%
 準(zhǔn)確度 + 15% 滿刻度 (3A ~ 5A); + 10% 滿刻度 (5A ~ 32A)
 | 
 
 | 遠(yuǎn)端控制 | 
 
 |  | 高電壓輸入 11V ~ 15V, 低電壓 0 ~ 4V 及低電流輸入 20mA 以下 | 
 
 | 測(cè)試模式 | 
 
 |  | 正常模式: 當(dāng)警告聲響起,,測(cè)試停止 連續(xù)模式:當(dāng)警告聲響起,,測(cè)試仍持續(xù)進(jìn)行
 | 
 
 | 蜂鳴器 | 
 
 |  | 當(dāng)測(cè)試失敗時(shí),,提供蜂鳴聲 | 
 
 | 測(cè)試頻率 | 
 
 |  | 50Hz 或 60Hz independent 視電源電壓而定 | 
 
 | 輸出信號(hào) | 
 
 |  | TEST, GO, NG, WARNING, READY, MONITOR | 
 
 | 使用電源 | 
 
 |  | 交流 100V/120V/220V/240V + 10%, 50/60Hz | 
 
 | 附件 | 
 
 |  | 電源線 x 1, 操作手冊(cè) x 1,
 測(cè)試線 GHT-115 x 1
 |